Suffix code
| Model |
Code |
Information |
| MP3- |
 |
 |
 |
 |
 |
Digital multi meter (dimension : 96×48 ㎜) |
| Displayable Digits |
4 |
|
|
|
|
4 digits (9999) |
| Input type |
AV |
|
|
|
AC(AC) voltmeter |
| AA |
|
|
|
AC(AC) ammeter |
| DV |
|
|
|
DC(DC) voltmeter |
| DA |
|
|
|
DC(DC) ammeter |
| AVR |
|
|
|
AC voltmeter(RMS) |
| AAR |
|
|
|
AC ammeter(RMS) |
| Output (Optional) |
N |
|
|
Only for displaying |
| 0 |
|
|
Relay(HI, GO, LO), measured Value output (4 - 20 ㎃ DC) |
| 1 |
|
|
Relay(HI, GO, LO) |
| 2 |
|
|
NPN Open collector(HI, GO, LO), BCD output(static) |
| 3 |
|
|
PNP Open collector(HI, GO, LO), BCD output(static) |
| 4 |
|
|
NPN Open collector(HI,GO,LO), measured Value output (4-20 ㎃) |
| 5 |
|
|
PNP Open collector(HI,GO,LO), measured Value output (4-20 ㎃) |
| 6 |
|
|
NPN Open collector(HI, GO, LO), serial output |
| 7 |
|
|
PNP Open collector(HI, GO, LO), serial output |
| 8 |
|
|
NPN Open collector(HI, GO, LO), communication (RS485) |
| 9 |
|
|
PNP Open collector(HI, GO, LO), communication (RS485) |
| 10 |
|
|
BCD output (dynamic) |
| 11 |
|
|
Relay(HI, GO, LO), RS485 output |
| Front panel type |
A |
|
Front acrylic type |
| B |
|
Front plane type |
| Front panel type |
|
None (100 - 240 V AC 50 - 60 ㎐) |
| C |
24 V DC (front division B, only applied with the name plate attached type) |
| ※ |
Please select the DC voltmeter because when measuring DC cuove 5A, users need to use exclusive shunt. |
| Model |
Code |
Information |
| MP6- |
 |
 |
 |
 |
 |
Digital multi meter (dimension : 72×36 ㎜) |
| Displayable Digits |
4 |
|
|
|
|
4 digits (9999) |
| Input type |
AV |
|
|
|
AC(AC) voltmeter |
| AA |
|
|
|
AC(AC) ammeter |
| DV |
|
|
|
DC(DC) voltmeter |
| DA |
|
|
|
DC(DC) ammeter |
| AVR |
|
|
|
AC voltmeter(RMS) |
| AAR |
|
|
|
AC ammeter(RMS) |
| Output (Optional) |
N |
|
|
Only for displaying |
| 0 |
|
|
Relay(HI, GO, LO), measured Value output (4 - 20 ㎃ DC) |
| 1 |
|
|
Relay(HI, GO, LO) |
| 4 |
|
|
NPN Open collector(HI,GO,LO), measured Value output (4-20 ㎃) |
| 5 |
|
|
PNP Open collector(HI,GO,LO), measured Value output (4-20 ㎃) |
| Front panel type |
A |
|
Front acrylic type |
| B |
|
Front plane type |
| Front panel type |
|
None (100 - 240 V AC 50 - 60 ㎐) |
| C |
24 V DC (front division B, only applied with the name plate attached type) |
Specification
| Model |
MP3-A |
MP3-B |
MP6-A |
MP6-B |
| Appearance |
|
|
|
|
| 96(W) x 48(H) x 112(D) |
72(W) x 36(H) x 100(D) |
| Power Supply |
100 - 240 V AC (50 - 60 ㎐) voltage fluctuation rate ±10 % |
| Power Consumption |
5 VA |
Approx. 4 VA |
| Display |
7 segment LED Display |
| Insulation Resistance |
100 MΩ min. (at 500 V DC) between external terminal and case |
| Dielectric Strength |
2000 V AC min. for 1 minute between external terminal and case |
| Noise Immunity |
By noise simulator, square-shaped wave noise, pulse width 1㎲, ±3000 V |
| Vibration Resistance |
| Malfunction Resistance : 10 - 55 ㎐ Single amplitude 0.5 ㎜ X·Y· Z each direction for 1 hour |
| Mechanical Durability : 10 - 55 ㎐ Single amplitude 0.75 ㎜ X·Y·Z each direction for 2 hours |
|
| Shock Resistance |
| Malfunction Resistance : 100 ㎨ for 3 times each in X·Y·Z direction, |
| Mechanical Durability: 300 ㎨ for 3 times each in X·Y·Z direction |
|
| Operating Ambient temperature |
-10 ~ +55 °C (with no freezing) |
| Operating Ambient Humidity |
35 ~ 85 % R.H. |
| Operating Circumstance |
With no corrosive gas |
| Storage Ambient Temperature |
-20 ~ 65 °C (with no freezing) |
| Relay Life Expectancy |