Mentor MP - High performance DC drive solution platform

25A to 7400A Two or four quadrant operation (regenerative)

24V - 480V / 500V - 575V / 500V - 690V

Mentor MP brings DC drive technology up to date, enabling existing and new DC motors to provide economic and productive service. DC drive technology remains cost effective, efficient and is relatively simple to implement. For new applications DC provides many advantages, especially for regenerative and high power applications.

 

Features

Greater motor field control

  • Built in field controller as standard
  • Gives excellent field control for the majority of DC motors
  • Reduces the need for external components

Enhanced field control with FXMP25

  • The FXMP25 may be controlled digitally by using a standard RJ45 connection, allowing set-up by standard drive parameters
  • The FXMP25 can also function in standalone mode using its integrated keypad and display

Enhanced system design

  • The heatsink cooling fans are intelligently controlled and only run when required, thus increasing reliability and reducing maintenance
  • Eighteen different option modules allow customisation of the drive, including fieldbus, Ethernet, I/O, extra feedback devices and motion controllers
  • The drive system designer is able to embed automation and motion control within the drive, eliminating communications delays that reduce performance

Fast set-up, configuration and monitoring

  • Quick and easy to set-up
  • Can be configured using optional removable keypads
  • Advanced autotune features help you get the best performance from your machine
  • PC software and Smartcard tools for rapid commissioning
  • Intelligent networked system with CTNet
  • Program inbuilt controller with SyPTLite
  • Develop tailored solutions for applications modules with SyPTPro
  • Option modules for all common Industrial Ethernet, fieldbus networks

Retro-fit projects

  • Easy integration with your existing motor, power supply, application equipment and communication networks has been ensured from the design stage
  • Mentor MP brings performance and possibilities to your application with minimum migration costs

Ease of migration

  • Mentor MP has been designed so existing Mentor II customers can easily migrate to the new platform
  • All power terminal locations and mounting points have been retained
  • Mentor MP has a much smaller frame size than the 900 A Mentor II with paralleling options to offer high power density
  • CT Soft has a built in migration wizard to assist with the transfer of drive parameters and programs
  • Smaller cable requirements make connections within the cubical easier. Construction of a custom-made bus-bar is not required

Motor Field Control

  • Built in field controller as standard in every Mentor MP
    • Gives excellent field control for the majority of DC motors
    • Reduces the need for external components

An external motor field controller is recommended when:

  • The required field current is greater than that offered by the standard drive, up to 25 A. For example, older motors with low field voltages
  • The field is required to be forced down more quickly than is possible with a standard half controlled field bridge
  • Applications can be implemented with simple field current reversal, without armature reversal, if machine dynamics can still be met

 

Spectifications

  • Models available for two or four quadrant (regenerative) operation 
  • 25A to 7400A, 24V - 480V / 500V - 575V / 500V - 690V 
  • Optional high-brightness LED or multi-language LCD keypad, simple configuration using plain text 
  • Modular parallel connection for higher power motor operation 
  • 12/24 pulse operation to minimize harmonics 
  • IP20 (NEMA 1) protection for size 1, IP10 (open chassis) for size 2A and 2B, and IP00 (open chassis) for size 2C and 2D for easy, low cost installation 
  • Integrated drive and motor protection for:
    • Over current
    • Over temperature
    • Phase loss
    • SCR/Thyristor junction temperature
    • Feedback loss
    • Field loss
    • Armature open circuit
  • Internal field controller with intelligent field weakening means that for 90% of applications no additional external controller is required
    • Frame size 1 to 8A
    • Frame size 2 to 20A
    • Flux control for enhanced open loop performance
  • Optional FXMP25 external field controller for current fields up to 25A
    • Digital link for field control from Mentor MP or Mentor II
    • Standalone digital control mode for simple application
    • Flux control for enhanced open loop performance
    • Intelligent field weakening
    • Field forcing – for high dynamic machine reversal
    • Field reversal – low dynamic machine reversing using two quadrant main stack 
  • Mentor MP has a field control mode for fields requiring greater than 25A 
  • Serial port for Modbus RTU and PC communications 
  • 3 Universal option module slots, allowing Mentor 
    MP to benefit from the solutions developed for Control Techniques market leading AC drive technology. 
    Each option slot allows:
    • High performance PLC and motion control
    • Ethernet and Fieldbus communications
    • Connectivity to additional feedback devices
    • Additional I/O
  • Galvanically isolated control 
  • Smartcard for drive parameter back-up and copying, allowing rapid installation and maintenance 
  • Integrated PLC as standard 
  • Standard software features for easy integration
    • PID controller
    • Motorized potentiometer
    • Digital lock (Slave operation from master encoder)
  • Open loop control using estimated speed advanced processing based on armature voltage and field flux feedback 
  • Closed loop control using
    • Tacho-generator feedback for connection to traditional DC motor
    • Incremental encoder feedback for higher accuracy and position control
    • Optional SinCos, SSI, Hiperface and EnDAT connectivity for high performance applications
  • High performance control strategy
    • 32 bit microprocessor
    • 35μs current sampling time
    • Speed controller and ramps update 250μs
    • Autotune features for armature, field current loops and speed loop

Current ratings

The power ratings for the 480V, 575V and 690V configurations are shown below.
The continuous current ratings given are for a maximum ambient temperature of 40°C (104°F) and an altitude of 1000m (3,300ft). For operation at higher temperatures and altitudes de-rating is required. Overload of 150% for 30s is available with ambient temperature of 40°C (104°F) up to a maximum of 10 repetitions per hour.

 

230V ratings 

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

 


240Vdc

A

A

A

 

hp

MP25A4(R)

22

25

37.5

 

5

MP45A4(R)

40

45

67.5

 

10

MP75A4(R)

67

75

112.5

 

20

MP105A4(R)

94

105

157.5

 

30

MP155A4(R)

139

155

232.5

 

40

MP210A4(R)

188

210

315

 

60

MP350A4(R)

313

350

525

 

100

MP420A4(R)

376

420

630

 

125

MP550A4(R)

492

550

825

 

150

MP700A4(R)

626

700

1050

 

200

MP825A4(R)

738

825

1237.5

 

225

MP900A4(R)

805

900

1350

 

250

MP1200A4(R)

1073

1200

1800

 

350

MP1850A4(R)

1655

1850

2775

 

550

 

480V ratings

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

 @ 400 Vdc

500 Vdc

A

A

A

kW

hp

MP25A4(R)

22

25

37.5

9

15

MP45A4(R)

40

45

67.5

15

27

MP75A4(R)

67

75

112.5

27

45

MP105A4(R)

94

105

157.5

37.5

60

MP155A4(R)

139

155

232.5

56

90

MP210A4(R)

188

210

315

75

125

MP350A4(R)

313

350

525

125

200

MP420A4(R)

376

420

630

150

250

MP550A4(R)

492

550

825

200

300

MP700A4(R)

626

700

1050

250

400

MP825A4(R)

738

825

1237.5

300

500

MP900A4(R)

805

900

1350

340

550

MP1200A4(R)

1073

1200

1800

450

750

MP1850A4(R)

1655

1850

2775

700

1150

 

 

575V ratings  

 

MODEL

AC INPUT
CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

 

CONTINUOUS

CONTINUOUS

150% OVERLOAD


@ 630 Vdc


@ 600
Vdc

A

A

A

kW

hp

MP25A5(R)

22

25

37.5

14

15

MP45A5(R)

40

45

67.5

25

30

MP75A5(R)

67

75

112.5

42

50

MP105A5(R)

94

105

157.5

58

75

MP155A5(R)

139

155

232.5

88

100

MP210A5(R)

188

210

315

120

150

MP350A5(R)

313

350

525

195

250

MP470A5(R)

420

470*

705

265

350

MP700A5(R)

626

700

1050

395

500

MP825A5(R)

738

825*

1237.5

465

600

MP1200A5(R)

1073

1200

1800

680

900

MP1850A5(R)

1655

1850

2775

1045

1400

*For this rating at 575V, 150% overload time is 20s at 40°C and 30s at 35°C

 

  690V ratings

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150%OVERLOAD

 

@ 760 Vdc

 

@ 700 Vdc

A

A

A

kW

hp

MP350A6(R)

313

350

525

240

300

MP470A6(R)

420

470*

705

320

400

MP700A6(R)

626

700

1050

480

600

MP825A6(R)

738

825*

1237.5

650

700

MP1200A6(R)

1073

1200

1800

850

1000

MP1850A6(R)

1655

1850

2775

1300

1600

 

 

* For this rating at 690V, 150% overload time is 20s at 40°C  and 30s at 35°C .

 

  Inputs and Outputs 

FUNCTION

QTY

I/O DEFAULT FUNCTION

RATING

Analog input 1

1


Speed ref 1

± 10V

Analog input 2

 

1

Speed ref 2

± 10V(default), 0-20mA or 4-20mA

Analog input 3

1

Motor thermistor

± 10V, 0-20mA, 4-20mA or Motor thermistor input (default)

Analog output

2

Speed feedback output

Current feedback output

± 10V(default), 0-20mA or 4-20mA

Digital input

3

Run reverse input

Local/Remote select

Jog forward input

+24V

Digital input / output

3

At speed output

Reset input

Run forward input

+24V

Relay

2


Drive OK indicator

Normally closed

Drive enable

1


Drive enable

+24V

+24V External input

1


External 24V supply

+24V

 

 

Conformance

  • Humidity 95% maximum (non condensing) at 40°C (104°F)
  • Ambient temperature -15°C to +40°C (5°F to +104°F), 55°C (131°F) with derating
  • Altitude: 0 to 3000m (9,900ft), derate 1% per 100m between 1000m (3,300ft) and 3000m (9,900ft)
  • Vibration: Tested in accordance with IEC 60068-2-64
  • Mechanical shock tested in accordance with IEC 60068-2-29
  • Storage temperature -40°C to +70°C (-40°F to +158°F)
  • Electromagnetic immunity complies with EN 61800-3 and EN 61000-6-2
  • Notch Immunity to IEC60146-1-1 class A
  • IEC 61800-5-1 Electrical safety
  • IEC 61131-2 I/O
  • EN 60529 Ingress protection
  • UL508C
  • EN 61000-6-4 EMC - with optional EMC filters
  • RoHS compliant 

 

 

MODEL

FRAME

ARMATURE CURRENT

(A)*

FIELD

CURRENT (A)

OVERALL DIMENSION

QUADRANTS OF 
OPERATION

480V

EN / IEC

cULus

 

575V

EN / IEC

cULus to 600V

690V

EN / IEC

Width 
(W)

Height 
(H)

Depth 
(D)

MP25A4(R)

MP25A5(R)

 

 

1A

 

25*

8

293mm (11.54in)

444mm (17.48in)

 

222mm (8.74in)

 

 

2 and 4

 

MP45A4(R)

MP45A5(R)

 

45*

MP75A4(R)

MP75A5(R)

 

75*

MP105A4(R)

MP105A5(R)

 

1B

105*

293mm (11.54in)

444mm (17.48in)

 

251mm (9.88in)

 

 

2 and 4

 

MP155A4(R)

MP155A5(R)

 

155*

MP210A4(R)

MP210A5(R)

 

210*

MP350A4(R)

MP350A5(R)

MP350A6(R)

2A

 

350*

20

495mm (19.49in)

640mm (25.20in)

 

301mm (11.85in)

 

 

2 and 4

 

MP420A4(R)

 

 

420*

 

MP470A5(R)

MP470A6(R)

470**

MP550A4(R)

 

 

550*

MP700A4(R)

MP700A5(R)

MP700A6(R)

 

2B

 

700*

495mm (19.49in)

640mm (25.20in)

 

301mm (11.85in)

 

 

2 and 4

 

MP825A4(R)

MP825A5(R)

MP825A6(R)

825**

MP900A4(R)

 

 

900*

MP1200A4

MP1200A5

MP1200A6

2C

1200*

555mm (21.85in)

1050mm

(41.34in)
***

611mm (24.06in)

2

 

MP1850A4

MP1850A5

MP1850A6

1850*

MP1200A4R

MP1200A5R

MP1200A6R

2D

1200*

555mm (21.85in)

1510mm (59.45in)

***

611mm (24.06in)

4

MP1850A4R

MP1850A5R

MP1850A6R

1850*

 

*Current ratings are at 40°C with 150% overload for 30s. **For this rating at 575V and 690V, 150% overload time is 20s at 40°C and 30s at 35°C.
***Height including optional fit exhaust duct cover is 1252mm (49.29in) for size 2C and 1712mm (67.40in) for size 2D.

7400A is achieved by parallel connection of Mentor MP drives