Airtac Solenoid valve
To make system realize the best performance, the control components must be precise and accurate. Component with good performance is the precondition to realize and exact action. Airtac has many types of control components for your choice.
CPV10S Series Integrated solenoid valve
- Integrated installation of air inlet/exhaust and power socket (25pin D-Sub) to save space and reduce additional accessories.
- Equipped with manual override for adjustment and troubleshooting.
- Low starting voltage and long service life.
CPV10 Series micro-solenoid valve
- With anti-surge component can avoid the damage of solenoid valve.
- Multi-direction installation and polarless circuit design.
- AC voltage models possess a built-in full wave rectifier circuit to reduce the noise effectively.
- Various of standard voltages: AC220V, AC110V, DC24V, DC12V.
- Low starting voltage and long service life.
- Equipped with a push-turn locking manual override for adjustment and troubleshooting.
CPV10 Series Manifold
- Integrated installation saves space and reduces additional accessories.
- Centralized air intake, exhaust, and wiring for quick air circuit checking.
- Fixible combination and expandability for various application. Blank plates are optional.
CPV15S Series Integrated solenoid valve (3/2 way)
- Integrated installation centralizes air intake, exhaust and power (25pin D-Sub) to save space and reduce additional accessories.
- Flexible combination and expandability for various applications. Blank plates are optional.
- Equipped with manual override for quick air circuit checking.
- Low starting voltage and long service life.
CPV15S Series Manifold, solenoid valve and blank plate (3/2 way)
- Integrated installation centralizes air inlet, exhaust and power (25pin D-Sub) to save space and reduce additional accessories.
- Flexible combination and expandability for various applications. Blank plates are optional.
CPV15 Series Micro-solenoid valve (3/2 way)
- None polarity design of DC circuit, the direction (vertical or horizontal) of wiring can be adjusted freely according to the installation demand.
- Low starting voltage and long service life.
- There is no buzzing by the usage of AC power supply.
- With surge device can avoid the damage of solenoid valve by surge voltage.
CPV15 Series Manifold (3/2 way)
- Integrated installation saves space and reduces additional accessories.
- Centralized air intake, exhaust, and wiring for quick air circuit checking.
- Flexible combination and expandability for various applications. Blank plates are optional.
3V1 Series solenoid valve (3/2 way)
- Direct acting type and normally closed mode, flexible in direction change.
- No need to add oil for lubrication.
- Several valves can be installed integrately to save installation space.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
3V2 Series solenoid valve (3/2 way)
- Direct acting type and normally closed mode, flexible in direction change.
- Normally closed and normally open types are optional.
- Structure in coaxial blanking mode: leakage proof and large air flow.
- No need to add oil for lubrication.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
3V2M Series solenoid valve (3/2 way)
- Direct acting type and normally closed mode, flexible in direction change.
- Normally closed and normally open types are optional.
- Structure in coaxial blanking mode: leakage proof and large air flow.
- No need to add oil for lubrication.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Valve needs to be used with the sub-base and allows various connection combinations to save space.
- It is easy to examine when there are faults owning to the unified air intake and exhaust and unified wiring.
- Flexible combination and strong expansion capability can make any combination or expansion of the numbers of direction control valves that are connected.
- Can adjust the installation direction of special sub-base seal for NO or NC functions.
3V3 Series solenoid valve (3/2 way)
- Direct acting type and normally closed mode, flexible in direction change.
- Normally closed and normally open types are optional.
- Structure in coaxial blanking mode: leakage proof and large air flow.
- No need to add oil for lubrication.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
3V100-300 Series solenoid valve (3/2 way)
- Pilot-oriented mode: Internal pilot or external pilot.
- Structure in sliding column mode: good tightness and sensitive reaction.
- Double control solenoid valves have memory function.
- Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.
- No need to add oil for lubrication.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
- Integrate with the manifold to save installation space.
6V Series solenoid valve (5/2 way, 5/3 way)
- Electrical entry is terminal, horizontal and vertical insertion can freely switch.
- Inner exhaust structure to collect pilot airflow, and then exhaust intensively from R, S port.
- Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.
- Threaded type and quick connector type are optional, and can integrate manifold to form valve group to save space.
6V Series Manifold (5/2 way, 5/3 way)
- It is available to integrate the direction control valves of the same series to form valve group to save space and cost.
- It is easy to examine when there are faults owning to the unified air intake and exhaust and unified wiring.
- Flexible combination and strong expansion capability can make any combination or expansion of the number of direction control valves that are connected.
7V Series Solenoid valve (5/2 way, 5/3 way)
- Electrical entry is terminal, horizontal and vertical insertion can freely switch.
- Inner exhaust structure, which can collect pilot air flow, and then exhaust intensively from R, S port.
- Die-cast molding with aluminum alloy for body. The shape of cavity is reasonable, which can increase valve’s flow.
Threaded type and quick connector type are optional, and can integrate manifold to form valve group to save space.
7V Series manifold
- It is available to integrate the direction control valves of the same series to form valve group to save space and cost.
- It is easy to examine when there are faults owning to the unified air intake and exhaust and unified wiring.
- Flexible combination and strong expansion capability can make any combination or expansion of the number of direction control valves that are connected.
4V100-400 Series solenoid valve (5/2 way, 5/3 way)
- Pilot-oriented mode: Internal pilot or external pilot.
- Structure in sliding column mode: good tightness and sensitive reaction.
- Three position solenoid valves have three kinds of central function for your choice.
- Double control solenoid valves have memory function.
- Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.
- No need to add oil for lubrication.
- It is available to form integrated valve group with the base to save installation space.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
4M(NAMUR) Series solenoid valve (5/2 way)
- Internally piloted structure.
- Structure in sliding column mode: good tightness and sensitive reaction.
- Double control solenoid valves have memory function.
- Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.
- No need to add oil for lubrication.
- Install in the side plate with the surface upward, which can be used by directly connecting with the actuators.
- Affiliated manual devices are equipped to facilitate installation and debugging.
- Several standard voltage grades are optional.
3V/4V Manifold valve
- It is available to integrate the direction control valves of the same series to form valve group to save space and cost.
- It is easy to examine when there are faults owning to the unified air intake and exhaust and unified wiring.
- Flexible combination and strong expansion capability can make any combination or expansion of the numbers of direction control valves that are connected.
ESV200, 300, 400, 600 Series (5/2 way, 5/3 way)
- Succinct appearance and compact conformation.
- The installation size conforms to ISO 5599/1 standard.
- Because of the special seals, the feature are large flow rate and long lifetime.
- For 200\300\400 series you can adjust the installation direction of the gasket to change the acting type: internal pilot, external pilot, or air control.
- You need install the valve together with the sub-base. There are individual and parallel type for manifold sub-base.
- There are various connection and installation method for manifold. It is easy to use.
- The manifold of 200\300\400 series have the function of exhaust throttling, so no need to connect another throttle valve.