Our limit switches have many types of actuator. Easy to use and have standard protection to use in hash environment.
1. Many types of actuator. Easy to use.
2. High mechanical strength
3. Oil-tight, water proof, Dust proof structure
TZ-1 |
Operation Speed |
0.5 mm to 50 cm/s |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5 mm |
|
Contact resistance |
25mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500 VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-5 to +65℃ |
|
Humidity |
95% RH |
|
Protection structure |
IP65 |
|
TZ-2 |
Operation Speed |
0.01 mm to 1 m/s |
Operating frequency |
Mechanically: 240 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5mm |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min.(500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-10 to +80℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP67 |
|
TZ-3 |
Operation Speed |
1 mm to 1 m/s |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 1,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5mm |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-10 to +70℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP67 |
|
TZ-5 |
Operation Speed |
1 mm to 2 m/s (TZ5104) |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 15,000,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5 mm |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-10 to +80℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP65 |
|
TZ-6 |
Type |
TZ-6001 |
TZ-6002 |
TZ-6003 |
TZ-6004 |
TZ-6043 |
TZ-6101 |
TZ-6102 |
TZ-6103 |
TZ-6104 |
TZ-6143 |
OF max. |
350g |
350g |
570g |
570g |
800g |
500g |
640g |
640g |
|||
RF min. |
114g |
114g |
170g |
170g |
240g |
100g |
230g |
230g |
|||
PT max. |
0.4mm |
0.5mm |
4mm |
4mm |
2mm |
1mm |
5mm |
5mm |
|||
OT min. |
5.5mm |
3.6mm |
6mm |
6mm |
5mm |
3.5mm |
6mm |
6mm |
|||
MD max. |
0.05mm |
0.05mm |
0.4mm |
0.4mm |
0.1mm |
0.12mm |
0.4mm |
0.4mm |
|||
OP |
38.2 |
49.7 |
- |
- |
45.8 |
49.7 |
- |
- |
TZ-7 |
Operation Speed |
0.01 mm to 50 cm/s (Pin Plunger) |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5 mm |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-10℃~+80℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP65 |
|
TZ-8 |
Operation Speed |
0.5 mm to 50 cm/s |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1,000 m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5 mm |
|
Contact resistance |
25 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-5 to +65℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP65 |
|
TZ-9 |
Operation Speed |
0.5 mm to 50 cm/s |
Operating frequency |
Mechanically: 120 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1000 m/S² (100G'S) |
|
Vibration |
10 to 55 HZ double amplitude 1.5 mm |
|
Contact resistance |
25 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz, for 1 minute between non-continuous terminals; |
|
Ambient temperature |
-5 to +65℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP65 |
|
TZ-93 |
Operation Speed |
0.1 m to 0.5 m/s |
Operating frequency |
Mechanically: 30 operation/min. |
|
Service life |
Mechanically: 10,000,000 operation/min. |
|
Shock |
Durability: 1,000m/S² (100G'S) |
|
Vibration |
10 to 55 Hz double amplitude 1.5 mm |
|
Contact resistance |
25 mΩ max. (initial value) |
|
Insulation resistance |
100 mΩ min. (500VDC) |
|
Dielectric strength |
2,500 VAC Umip 4KV |
|
Ambient temperature |
-30 to +70℃ |
|
Humidity |
95 %RH |
|
Protection structure |
IP65 |
1.Many types of actuator. Design with adjustable position of action (e.g., TM1701)
2.High breaking capacity (20A)
3.High precision
4.Wide operating speed range